Relays & Buzzers Relays: Plug in type or solder terminal type (MY,LY,MK2P) Having coil voltage:12,24,36,48,110,230V for DC & 24,36,48,110,230VAC.
Timers & Protection Relays We have Timers & Protection Relays, Delay ON Timer SZR-60 Star & Delta Relay SYU Phase Protection Relay SFMK-03 Phase Protection Relay SFMK-A Smallest Full Functional Phase Protection Relay FULL MP Monophase Under & Over Voltage Protection Relay. SKAD-01 Three Phase/ Mono phase Under & Over Voltage Protection Relay. SKAD 04 For more details please down load our catalogue.
Delay on Timer
TYPE
SZR 60
ORDER CODE
GENERAL SPECIFICATIONS
SZR is Delay ON timers. When SZR is energized “ON” led is on and counter begins to count and after adjusted time relay change position to “OFF”.
SETTING ACCURACY
2% of whole scale
OUTPUT CONTACT
SPDT Relay (1 inversor) 10A / 250 Vac(Omron) (Resistive Load)
SUPPLY VOLTAGE
230 Vac ± %20 (L - N), 50 / 60 Hz
POWER CONSUMPTION
< 7 VA
OPERATING TEMPERATURE
-5 °C...+55 °C
ELECTIRICAL CONNECTION
PCB Connector
ELECTIRICAL LIFE
100.000 ON / OFF (Resistive Load )
MOUNTING TYPE
For Mounting on DIN Rail or Inside Panel
PROTECTION CLASS
IP 20
DIMENSIONS
AS PER CATALOG.
WEIGHT
SZR: 0,09 kg
Multifunction & Range Timer
SZR M1
SZR M1: 60000
- Multifunctional * Delay ON * Delay OFF * Symmetrical Recycle (ON start) * Symmetrical Recycle (OFF start) - Multi Range * 7 time Ranges covering from 0.06 sec till 30 hours - Knob Adjustable time ranges, time multiplier and functions a. Time: Multiplier that adjust time within setted time rang b. Range: Time range that is for more precise setting. c. Func. : Functions (shown below) - Led displays that shows the Supply is On.
FUNCTIONS
F1: Delay ON F2: Delay OFF F3: Symmetrical Recycle (ON start) F4: Symmetrical Recycle (OFF start) OFF: Cuts the output.
TIME RANGE
0,06 s...30 h
%2 of whole scale
SPDT Relay (1 inversor) 6A / 250 Vac (Resistive Load)
230 Vac � %20 (L - N), 50 / 60 Hz 24 Vac � %10 (B1 - B2) 24 Vdc � %10 (B1:+ B2: 0) * Please indicate Voltage ratings at order. 110V AC is also available upon request.
< 7 VA (230 Vac) <1,3 VA (24 Vac) <1 VA (24 Vdc)
-5�C...+55 �C
ELECTRICAL CONNECTION
100.000 On /Off (Resistive Load)
Figure 5
0,09 kg
Star & Delta Relay
230 Vac ± %20 (L - N), 50 / 60 Hz 24 Vac ± %10 (B1 - B2) 24 Vdc ± %10 (B1:+ B2: 0) * Please indicate Voltage ratings at order. 110V AC is also available upon request.
-5°C...+55 °C
Asymmetry 40% Fixed
SFMK / FMK
See Table
Phase Protection Relay are for protecting motors in 3 phase systems from Phase Failure, Phase Asymmetry, Sequence and over heat situations. These functions are shown below. 1) Phase Sequence: If the phase are not in right Sequence Relay never energize the system. 2) Phase Failure: If one of the phases are lost for any reason relay cuts the output for protecting the motor. 3) PTC Protection: PTC is placed to the motor and if it increases over the 2 Kohm it cuts the output. 4) Phase asymmetry: if between phases asymmetry is more than tolerance cuts the system.
220 Vac (L1 - N), 50 / 60 Hz
SPDT Relay (1 inversor) 10A / 250 Vac (Resistive Load)
SFMK: PCB Connector / FMK: Raising Clamp
For Mounting on DIN Rail
Asymmetry 10-30%
Smallest Full Functional Phase Full MP Phase / Motor Protection Relay,Phase sequence & Phase failure Device without neutral. Protect Motor from Phase loss,Phase sequence failure,Phase asymmetry
Monophase Under & Over Voltage
3Phase / Monophase Under & Over Voltage
Buzzer Model No. CBZ - 10 Specification : - Mounting Style - Surface Mount. Volume In dB - 8 Weight in Gms - 160 Operating Voltage - AC : - 110, 220, 380V DC:- 12 &24V Model No. CBZ - 20 Specification : - Mounting Style - Flush Mount. Volume In dB - 8 Weight in Gms - 190 Operating Voltage - AC : - 110, 220, 380V DC:- 12 &24V Model No. CBZ - 30 Specification : - Mounting Style - Flush Mount. Volume In dB - 8 Weight in Gms - 160 Operating Voltage - AC : - 110, 220V DC: -12 &24V