Schneider Electric 

Products

ACB
Automatic Source Changeover System
Cable Ends
Capacitors
Capacitors Duty Contactors
Contactor
Control Relays
Control Relays
Distribution Board
ELCB
Indicating Lamp & Push Buttons
Industrial Automation
Interpact Switch Disconnector
Limit Switches
LTMR Relays
MCB
MCCB
Meters (Digital)
MPCB
Pendant Control & Joystick
Plastic / Metal – Plug / Sockets
Plug-In-Relays
Power Contactors
Reversing Contactors
Start Delta / DOL Starters
Switch Disconnector Fuse
Vacuum Contactors
Description | Benefits | Applications
Contractors-thermal-relay 7 contactor sizes from 6 to 300 A
2.2 kW to 160 kW (AC3 / 415 V)
Width from 45 mm (6 A) to 213 mm (300 A)
3 poles
AC control
Contractors-thermal-relay

4 thermal overload relay sizes from 0.1 to 333 A
For all TeSys E contactors
Class 10A
Direct mounting under contactors

4 Key accessory types
Control: Auxiliary Contact Block
Reverser Starter : mechanical interlock
Star-Delta: Time delay auxiliary contact block
Terminal block for thermal overload relay

1 control relay range
3 types of control relays with 4 NO/NC
contacts: 2+2, 3+1 and 4+0

Standardized certified solutions
IEC 60947-4-1
IEC 60947-5-1
CE
GOST

AC, DC, low - consumption DC control circuit
All types of starter : reversing or non - reversing,
   star / delta, by auto - transformer, etc
Connectors : spring terminal, EverLink terminal block,
  screw clamp, ring-type connection, Faston connector.
Easy and simple direct mounting beetween contactor
  and circuit breaker, according to EverLink terminal block
  (from 40 to 65 A)
Description | Benefits | Applications
sealable flap Manual and automatic reset
Sealable flap
Prewiring kit
Terminal block for separate mounting
Remote electrical reset
Can be combined with TeSys model d contactors in a 45 mm wide space up to 18.5 kW, 55 mm from 15 to 30 kW
Connectors: spring terminal, screw clamp,
terminal block EverLink (LRD3)
Class 10 A & class 20.
Description | Benefits | Applications
Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
Motor protection provided by thermal-magnetic devices built into the circuit-breaker
No live parts are accessible to direct finger contact
The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
The addition of a shunt trip enables remote control of tripping
The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
Connectors : spring terminal, screw clamp
Designed & Hosted by : MID  Promoted by : GID